benikigai/ec-1Public
EC-1 Wireless Controller
Synthetic example. Every value is made up to show the format.
Factory · Quality
Quality
How is every unit checked, and against what limits?
- 6
- inspection plans
- 11
- tests
- 10 of 11
- tests with limits
| Station | Incoming | In-process | Final | Outgoing | Tests | All |
|---|---|---|---|---|---|---|
| IQC-1 Incoming inspection | 3 | 3 | ||||
| A4 Close and screw | 1 | 1 | ||||
| T1 Flash test image and RF test | 3 | 3 | ||||
| T2 Functional test and stick calibration | 5 | 5 | ||||
| T3 Cosmetic and gap check | 1 | 1 | 2 | |||
| T4 Charge and battery test | 2 | 2 | ||||
| OQC-1 Outgoing audit | 1 | 1 |
Inspection plans
| Stage | Characteristic | Item | Station | Sampling | AQL | Sample | Method |
|---|---|---|---|---|---|---|---|
| IQC | Length, width and stick hole diameter; cosmetic grade Ainsp:shell-iqc | Top shell | Incoming inspection | ANSI/ASQ Z1.4 level II lots 1201 to 3200 general inspection level II, normal inspection InferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 1 | 125 | caliper and pin gauge; light boothInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
| IQC | Centre return and full travel resistanceinsp:stick-iqc | Analog stick module | Incoming inspection | ANSI/ASQ Z1.4 level II lots 1201 to 3200 general inspection level II, normal inspection InferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 0.65 | 125 | fixture with ohmmeterInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
| IQC | Open-circuit voltage 3.75 to 3.90 V; thickness at most 6.1 mminsp:cell-iqc | Li-ion pouch cell, 600 mAh | Incoming inspection | ANSI/ASQ Z1.4 level II lots 1201 to 3200 general inspection level II, normal inspection InferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 0.4 | 125 | OCV meter and caliperInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
| IPQC | Breakaway torque 0.16 to 0.22 N·minsp:screw-audit | Drive four M2 screws to 0.18 N·m | Close and screw | other | — | 5 | torque audit gauge, 5 units per hourInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
| FQC | No scratch over 0.3 mm in zone A; shoulder gap 0.10 to 0.30 mminsp:cosmetic-100 | EC-1, closed unit | Cosmetic and gap check | 100% | — | — | camera arch and feeler gaugeInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
| OQC | Full functional, pack contents, label, drop 1.2 m on 1 unit per lotinsp:oqc | Packed unit | Outgoing audit | ANSI/ASQ Z1.4 level II lots 501 to 1200 general inspection level II, normal inspection InferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 0.65 | 80 | full test setInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Tests
| Test | Station | Measures | Lower limit | Upper limit |
|---|---|---|---|---|
Test image flashed and verifiedtest:flash-ok | Flash test image and RF test | image checksum | none | none |
Radiated output powertest:rf-power | Flash test image and RF test | TX power at 2440 MHz | -6 dBmInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 4 dBmInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Receive sensitivitytest:rf-rssi | Flash test image and RF test | RSSI from reference tag at 1 m | -70 dBmInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | none |
Stick centre at rest, after calibrationtest:stick-centre | Functional test and stick calibration | centre offset | none | 1 % of full scaleInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Stick range, each axistest:stick-range | Functional test and stick calibration | full-scale reach | 96 % of full scaleInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | none |
Face button actuation forcetest:button-force | Functional test and stick calibration | force at contact | 150 gfInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 210 gfInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Gyro zero-rate biastest:imu-bias | Functional test and stick calibration | bias, each axis | none | 2 deg/sInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
LRA drive currenttest:haptic-current | Functional test and stick calibration | RMS current at 170 Hz | 40 mAInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 90 mAInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Charge current at 5 Vtest:charge-current | Charge and battery test | input current | 280 mAInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 360 mAInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Cell voltage after 20 s chargetest:cell-voltage | Charge and battery test | cell voltage | 3.7 VInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 4.05 VInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |
Gap at shoulder buttonstest:shoulder-gap | Cosmetic and gap check | feeler gauge | 0.1 mmInferredEngineering judgement, not measured. Medium confidence.No evidence listed. | 0.3 mmInferredEngineering judgement, not measured. Medium confidence.No evidence listed. |