stationcheckmethodreaction
S1stake pull-off, first five each shiftpush-out testerstop and reset the staker
S3torque and angle window, every screwdriver controllerreject the unit to rework
S4bead present and placed, every unitbead camerawipe and redispense
S52 N tug after mating, every unitseating toolreseat once, then reject
S6ring polarity, pad height, key position and the close force curve, every unitpolarity and height gauges, press monitorreject the unit
S7flash hash, unit ID once, calibration limitstest PCreflash once, then reject
S8full functional test including wireless charge, and QR read-backfunctional testerreject to failure analysis