benikigai/ec-1Public

EC-1 Wireless Controller

test-plan.yaml · 2.5 KB · commit #1 · Nov 1, 2026

SHA-256 ddeb6f3372822e8f5f19916629b2959ea1e523b5aeb935ef2475ffcd2ca4020e

# SYNTHETIC. Same as tests in opd.yaml.
tests:
- id: test:flash-ok
  station: sta:t1
  name: Test image flashed and verified
  measures: image checksum
- id: test:rf-power
  station: sta:t1
  name: Radiated output power
  measures: TX power at 2440 MHz
  lower:
    value: -6.0
    unit: dBm
    source: inferred
    confidence: medium
  upper:
    value: 4.0
    unit: dBm
    source: inferred
    confidence: medium
- id: test:rf-rssi
  station: sta:t1
  name: Receive sensitivity
  measures: RSSI from reference tag at 1 m
  lower:
    value: -70.0
    unit: dBm
    source: inferred
    confidence: medium
- id: test:stick-centre
  station: sta:t2
  name: Stick centre at rest, after calibration
  measures: centre offset
  upper:
    value: 1.0
    unit: '% of full scale'
    source: inferred
    confidence: medium
- id: test:stick-range
  station: sta:t2
  name: Stick range, each axis
  measures: full-scale reach
  lower:
    value: 96.0
    unit: '% of full scale'
    source: inferred
    confidence: medium
- id: test:button-force
  station: sta:t2
  name: Face button actuation force
  measures: force at contact
  lower:
    value: 150.0
    unit: gf
    source: inferred
    confidence: medium
  upper:
    value: 210.0
    unit: gf
    source: inferred
    confidence: medium
- id: test:imu-bias
  station: sta:t2
  name: Gyro zero-rate bias
  measures: bias, each axis
  upper:
    value: 2.0
    unit: deg/s
    source: inferred
    confidence: medium
- id: test:haptic-current
  station: sta:t2
  name: LRA drive current
  measures: RMS current at 170 Hz
  lower:
    value: 40.0
    unit: mA
    source: inferred
    confidence: medium
  upper:
    value: 90.0
    unit: mA
    source: inferred
    confidence: medium
- id: test:charge-current
  station: sta:t4
  name: Charge current at 5 V
  measures: input current
  lower:
    value: 280.0
    unit: mA
    source: inferred
    confidence: medium
  upper:
    value: 360.0
    unit: mA
    source: inferred
    confidence: medium
- id: test:cell-voltage
  station: sta:t4
  name: Cell voltage after 20 s charge
  measures: cell voltage
  lower:
    value: 3.7
    unit: V
    source: inferred
    confidence: medium
  upper:
    value: 4.05
    unit: V
    source: inferred
    confidence: medium
- id: test:shoulder-gap
  station: sta:t3
  name: Gap at shoulder buttons
  measures: feeler gauge
  lower:
    value: 0.1
    unit: mm
    source: inferred
    confidence: medium
  upper:
    value: 0.3
    unit: mm
    source: inferred
    confidence: medium