benikigai/ec-1Public
EC-1 Wireless Controller
SHA-256 ddeb6f3372822e8f5f19916629b2959ea1e523b5aeb935ef2475ffcd2ca4020e
# SYNTHETIC. Same as tests in opd.yaml.
tests:
- id: test:flash-ok
station: sta:t1
name: Test image flashed and verified
measures: image checksum
- id: test:rf-power
station: sta:t1
name: Radiated output power
measures: TX power at 2440 MHz
lower:
value: -6.0
unit: dBm
source: inferred
confidence: medium
upper:
value: 4.0
unit: dBm
source: inferred
confidence: medium
- id: test:rf-rssi
station: sta:t1
name: Receive sensitivity
measures: RSSI from reference tag at 1 m
lower:
value: -70.0
unit: dBm
source: inferred
confidence: medium
- id: test:stick-centre
station: sta:t2
name: Stick centre at rest, after calibration
measures: centre offset
upper:
value: 1.0
unit: '% of full scale'
source: inferred
confidence: medium
- id: test:stick-range
station: sta:t2
name: Stick range, each axis
measures: full-scale reach
lower:
value: 96.0
unit: '% of full scale'
source: inferred
confidence: medium
- id: test:button-force
station: sta:t2
name: Face button actuation force
measures: force at contact
lower:
value: 150.0
unit: gf
source: inferred
confidence: medium
upper:
value: 210.0
unit: gf
source: inferred
confidence: medium
- id: test:imu-bias
station: sta:t2
name: Gyro zero-rate bias
measures: bias, each axis
upper:
value: 2.0
unit: deg/s
source: inferred
confidence: medium
- id: test:haptic-current
station: sta:t2
name: LRA drive current
measures: RMS current at 170 Hz
lower:
value: 40.0
unit: mA
source: inferred
confidence: medium
upper:
value: 90.0
unit: mA
source: inferred
confidence: medium
- id: test:charge-current
station: sta:t4
name: Charge current at 5 V
measures: input current
lower:
value: 280.0
unit: mA
source: inferred
confidence: medium
upper:
value: 360.0
unit: mA
source: inferred
confidence: medium
- id: test:cell-voltage
station: sta:t4
name: Cell voltage after 20 s charge
measures: cell voltage
lower:
value: 3.7
unit: V
source: inferred
confidence: medium
upper:
value: 4.05
unit: V
source: inferred
confidence: medium
- id: test:shoulder-gap
station: sta:t3
name: Gap at shoulder buttons
measures: feeler gauge
lower:
value: 0.1
unit: mm
source: inferred
confidence: medium
upper:
value: 0.3
unit: mm
source: inferred
confidence: medium