SOP: Functional test and stick calibration (sta:t2)
SYNTHETIC example. Rev C, 2026-10-14.
Operators: 1
Equipment: stick actuation robot, button press head, IMU turntable
Steps
- Stick centre and range calibration (op:stick-cal). Robot sweeps the stick to 8 points and centre. Target 15 s.
- Buttons, IMU, haptics and LED (op:functional). Press head, 90 degree turntable step, LRA current. Target 12 s.
Tests and limits
| Test | Lower | Upper |
|---|---|---|
| Stick centre at rest, after calibration | 1.0 % of full scale | |
| Stick range, each axis | 96.0 % of full scale | |
| Face button actuation force | 150.0 gf | 210.0 gf |
| Gyro zero-rate bias | 2.0 deg/s | |
| LRA drive current | 40.0 mA | 90.0 mA |
Watch for
- Seat the unit in the robot nest, stick up.
- The robot sweeps the stick through 8 points and centre, then writes the calibration.
- Three fails in an hour: hold the line and call IQC to check the stick module lot.
Risks at this station (PFMEA)
- Calibration out of range: RPN 32 (fm:stick-cal-fail)